2023 January 25 03:10 | Model Family: Seagate BarraCuda 3.5 | User Capacity: 1,000,204,886,016 bytes [1.00 TB]



SMART overall-health self-assessment test result: PASSED
          9 Power_On_Hours          0x0032   099   099   000    Old_age   Always       -       976
        197 Current_Pending_Sector  0x0012   100   100   000    Old_age   Always       -       0
        198 Offline_Uncorrectable   0x0010   100   100   000    Old_age   Offline      -       0
        
smartctl 7.2 2020-12-30 r5155 [i686-linux-5.10.0-20-686-pae] (local build) Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Seagate BarraCuda 3.5 Device Model: ST1000DM010-2EP102 Serial Number: Hidden LU WWN Device Id: 5 000c50 0b36bbece Firmware Version: CC43 User Capacity: 1,000,204,886,016 bytes [1.00 TB] Sector Sizes: 512 bytes logical, 4096 bytes physical Rotation Rate: 7200 rpm Form Factor: 3.5 inches Device is: In smartctl database [for details use: -P show] ATA Version is: ATA8-ACS T13/1699-D revision 4 SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s) Local Time is: Wed Jan 25 04:10:04 2023 CET SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 0) seconds. Offline data collection capabilities: (0x73) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. No Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 105) minutes. Conveyance self-test routine recommended polling time: ( 2) minutes. SCT capabilities: (0x1085) SCT Status supported. SMART Attributes Data Structure revision number: 10 Vendor Specific SMART Attributes with Thresholds: ID ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000f 076 066 006 Pre-fail Always - 0/44907736 3 Spin_Up_Time 0x0003 097 097 000 Pre-fail Always - 0 4 Start_Stop_Count 0x0032 100 100 020 Old_age Always - 187 5 Reallocated_Sector_Ct 0x0033 100 100 010 Pre-fail Always - 0 7 Seek_Error_Rate 0x000f 066 060 045 Pre-fail Always - 0/3863540 9 Power_On_Hours 0x0032 099 099 000 Old_age Always - 976 10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0 12 Power_Cycle_Count 0x0032 100 100 020 Old_age Always - 187 183 Runtime_Bad_Block 0x0032 100 100 000 Old_age Always - 0 184 End-to-End_Error 0x0032 100 100 099 Old_age Always - 0 187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0 188 Command_Timeout 0x0032 100 100 000 Old_age Always - 0 0 0 189 High_Fly_Writes 0x003a 100 100 000 Old_age Always - 0 190 Airflow_Temperature_Cel 0x0022 070 061 040 Old_age Always - 30 (Min/Max 23/33) 193 Load_Cycle_Count 0x0032 100 100 000 Old_age Always - 201 194 Temperature_Celsius 0x0022 030 016 000 Old_age Always - 30 (0 16 0 0 0) 195 Hardware_ECC_Recovered 0x001a 004 001 000 Old_age Always - 44907736 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0 240 Head_Flying_Hours 0x0000 100 253 000 Old_age Offline - 975h+20m+55.459s 241 Total_LBAs_Written 0x0000 100 253 000 Old_age Offline - 2551849308 242 Total_LBAs_Read 0x0000 100 253 000 Old_age Offline - 371476775 SMART Error Log Version: 1 No Errors Logged SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error 1 Short offline Completed without error 00% 815 - 2 Short offline Completed without error 00% 815 - 3 Short offline Completed without error 00% 815 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay.